Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EBioMedicine ; 102: 105075, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38565004

RESUMO

BACKGROUND: AI models have shown promise in performing many medical imaging tasks. However, our ability to explain what signals these models have learned is severely lacking. Explanations are needed in order to increase the trust of doctors in AI-based models, especially in domains where AI prediction capabilities surpass those of humans. Moreover, such explanations could enable novel scientific discovery by uncovering signals in the data that aren't yet known to experts. METHODS: In this paper, we present a workflow for generating hypotheses to understand which visual signals in images are correlated with a classification model's predictions for a given task. This approach leverages an automatic visual explanation algorithm followed by interdisciplinary expert review. We propose the following 4 steps: (i) Train a classifier to perform a given task to assess whether the imagery indeed contains signals relevant to the task; (ii) Train a StyleGAN-based image generator with an architecture that enables guidance by the classifier ("StylEx"); (iii) Automatically detect, extract, and visualize the top visual attributes that the classifier is sensitive towards. For visualization, we independently modify each of these attributes to generate counterfactual visualizations for a set of images (i.e., what the image would look like with the attribute increased or decreased); (iv) Formulate hypotheses for the underlying mechanisms, to stimulate future research. Specifically, present the discovered attributes and corresponding counterfactual visualizations to an interdisciplinary panel of experts so that hypotheses can account for social and structural determinants of health (e.g., whether the attributes correspond to known patho-physiological or socio-cultural phenomena, or could be novel discoveries). FINDINGS: To demonstrate the broad applicability of our approach, we present results on eight prediction tasks across three medical imaging modalities-retinal fundus photographs, external eye photographs, and chest radiographs. We showcase examples where many of the automatically-learned attributes clearly capture clinically known features (e.g., types of cataract, enlarged heart), and demonstrate automatically-learned confounders that arise from factors beyond physiological mechanisms (e.g., chest X-ray underexposure is correlated with the classifier predicting abnormality, and eye makeup is correlated with the classifier predicting low hemoglobin levels). We further show that our method reveals a number of physiologically plausible, previously-unknown attributes based on the literature (e.g., differences in the fundus associated with self-reported sex, which were previously unknown). INTERPRETATION: Our approach enables hypotheses generation via attribute visualizations and has the potential to enable researchers to better understand, improve their assessment, and extract new knowledge from AI-based models, as well as debug and design better datasets. Though not designed to infer causality, importantly, we highlight that attributes generated by our framework can capture phenomena beyond physiology or pathophysiology, reflecting the real world nature of healthcare delivery and socio-cultural factors, and hence interdisciplinary perspectives are critical in these investigations. Finally, we will release code to help researchers train their own StylEx models and analyze their predictive tasks of interest, and use the methodology presented in this paper for responsible interpretation of the revealed attributes. FUNDING: Google.


Assuntos
Algoritmos , Catarata , Humanos , Cardiomegalia , Fundo de Olho , Inteligência Artificial
2.
Nat Biomed Eng ; 7(6): 756-779, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37291435

RESUMO

Machine-learning models for medical tasks can match or surpass the performance of clinical experts. However, in settings differing from those of the training dataset, the performance of a model can deteriorate substantially. Here we report a representation-learning strategy for machine-learning models applied to medical-imaging tasks that mitigates such 'out of distribution' performance problem and that improves model robustness and training efficiency. The strategy, which we named REMEDIS (for 'Robust and Efficient Medical Imaging with Self-supervision'), combines large-scale supervised transfer learning on natural images and intermediate contrastive self-supervised learning on medical images and requires minimal task-specific customization. We show the utility of REMEDIS in a range of diagnostic-imaging tasks covering six imaging domains and 15 test datasets, and by simulating three realistic out-of-distribution scenarios. REMEDIS improved in-distribution diagnostic accuracies up to 11.5% with respect to strong supervised baseline models, and in out-of-distribution settings required only 1-33% of the data for retraining to match the performance of supervised models retrained using all available data. REMEDIS may accelerate the development lifecycle of machine-learning models for medical imaging.


Assuntos
Aprendizado de Máquina , Aprendizado de Máquina Supervisionado , Diagnóstico por Imagem
3.
Elife ; 122023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36975205

RESUMO

Biological age, distinct from an individual's chronological age, has been studied extensively through predictive aging clocks. However, these clocks have limited accuracy in short time-scales. Here we trained deep learning models on fundus images from the EyePACS dataset to predict individuals' chronological age. Our retinal aging clocking, 'eyeAge', predicted chronological age more accurately than other aging clocks (mean absolute error of 2.86 and 3.30 years on quality-filtered data from EyePACS and UK Biobank, respectively). Additionally, eyeAge was independent of blood marker-based measures of biological age, maintaining an all-cause mortality hazard ratio of 1.026 even when adjusted for phenotypic age. The individual-specific nature of eyeAge was reinforced via multiple GWAS hits in the UK Biobank cohort. The top GWAS locus was further validated via knockdown of the fly homolog, Alk, which slowed age-related decline in vision in flies. This study demonstrates the potential utility of a retinal aging clock for studying aging and age-related diseases and quantitatively measuring aging on very short time-scales, opening avenues for quick and actionable evaluation of gero-protective therapeutics.


Assuntos
Envelhecimento , Estudo de Associação Genômica Ampla , Humanos , Pré-Escolar , Envelhecimento/genética , Retina , Fundo de Olho , Diagnóstico por Imagem , Epigênese Genética
4.
Lancet Digit Health ; 5(5): e257-e264, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36966118

RESUMO

BACKGROUND: Photographs of the external eye were recently shown to reveal signs of diabetic retinal disease and elevated glycated haemoglobin. This study aimed to test the hypothesis that external eye photographs contain information about additional systemic medical conditions. METHODS: We developed a deep learning system (DLS) that takes external eye photographs as input and predicts systemic parameters, such as those related to the liver (albumin, aspartate aminotransferase [AST]); kidney (estimated glomerular filtration rate [eGFR], urine albumin-to-creatinine ratio [ACR]); bone or mineral (calcium); thyroid (thyroid stimulating hormone); and blood (haemoglobin, white blood cells [WBC], platelets). This DLS was trained using 123 130 images from 38 398 patients with diabetes undergoing diabetic eye screening in 11 sites across Los Angeles county, CA, USA. Evaluation focused on nine prespecified systemic parameters and leveraged three validation sets (A, B, C) spanning 25 510 patients with and without diabetes undergoing eye screening in three independent sites in Los Angeles county, CA, and the greater Atlanta area, GA, USA. We compared performance against baseline models incorporating available clinicodemographic variables (eg, age, sex, race and ethnicity, years with diabetes). FINDINGS: Relative to the baseline, the DLS achieved statistically significant superior performance at detecting AST >36·0 U/L, calcium <8·6 mg/dL, eGFR <60·0 mL/min/1·73 m2, haemoglobin <11·0 g/dL, platelets <150·0 × 103/µL, ACR ≥300 mg/g, and WBC <4·0 × 103/µL on validation set A (a population resembling the development datasets), with the area under the receiver operating characteristic curve (AUC) of the DLS exceeding that of the baseline by 5·3-19·9% (absolute differences in AUC). On validation sets B and C, with substantial patient population differences compared with the development datasets, the DLS outperformed the baseline for ACR ≥300·0 mg/g and haemoglobin <11·0 g/dL by 7·3-13·2%. INTERPRETATION: We found further evidence that external eye photographs contain biomarkers spanning multiple organ systems. Such biomarkers could enable accessible and non-invasive screening of disease. Further work is needed to understand the translational implications. FUNDING: Google.


Assuntos
Aprendizado Profundo , Retinopatia Diabética , Humanos , Estudos Retrospectivos , Cálcio , Retinopatia Diabética/diagnóstico , Biomarcadores , Albuminas
5.
Nat Biomed Eng ; 6(12): 1370-1383, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35352000

RESUMO

Retinal fundus photographs can be used to detect a range of retinal conditions. Here we show that deep-learning models trained instead on external photographs of the eyes can be used to detect diabetic retinopathy (DR), diabetic macular oedema and poor blood glucose control. We developed the models using eye photographs from 145,832 patients with diabetes from 301 DR screening sites and evaluated the models on four tasks and four validation datasets with a total of 48,644 patients from 198 additional screening sites. For all four tasks, the predictive performance of the deep-learning models was significantly higher than the performance of logistic regression models using self-reported demographic and medical history data, and the predictions generalized to patients with dilated pupils, to patients from a different DR screening programme and to a general eye care programme that included diabetics and non-diabetics. We also explored the use of the deep-learning models for the detection of elevated lipid levels. The utility of external eye photographs for the diagnosis and management of diseases should be further validated with images from different cameras and patient populations.


Assuntos
Aprendizado Profundo , Retinopatia Diabética , Doenças Retinianas , Humanos , Sensibilidade e Especificidade , Retinopatia Diabética/diagnóstico por imagem , Fundo de Olho
6.
Lancet Digit Health ; 3(1): e10-e19, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33735063

RESUMO

BACKGROUND: Diabetic retinopathy screening is instrumental to preventing blindness, but scaling up screening is challenging because of the increasing number of patients with all forms of diabetes. We aimed to create a deep-learning system to predict the risk of patients with diabetes developing diabetic retinopathy within 2 years. METHODS: We created and validated two versions of a deep-learning system to predict the development of diabetic retinopathy in patients with diabetes who had had teleretinal diabetic retinopathy screening in a primary care setting. The input for the two versions was either a set of three-field or one-field colour fundus photographs. Of the 575 431 eyes in the development set 28 899 had known outcomes, with the remaining 546 532 eyes used to augment the training process via multitask learning. Validation was done on one eye (selected at random) per patient from two datasets: an internal validation (from EyePACS, a teleretinal screening service in the USA) set of 3678 eyes with known outcomes and an external validation (from Thailand) set of 2345 eyes with known outcomes. FINDINGS: The three-field deep-learning system had an area under the receiver operating characteristic curve (AUC) of 0·79 (95% CI 0·77-0·81) in the internal validation set. Assessment of the external validation set-which contained only one-field colour fundus photographs-with the one-field deep-learning system gave an AUC of 0·70 (0·67-0·74). In the internal validation set, the AUC of available risk factors was 0·72 (0·68-0·76), which improved to 0·81 (0·77-0·84) after combining the deep-learning system with these risk factors (p<0·0001). In the external validation set, the corresponding AUC improved from 0·62 (0·58-0·66) to 0·71 (0·68-0·75; p<0·0001) following the addition of the deep-learning system to available risk factors. INTERPRETATION: The deep-learning systems predicted diabetic retinopathy development using colour fundus photographs, and the systems were independent of and more informative than available risk factors. Such a risk stratification tool might help to optimise screening intervals to reduce costs while improving vision-related outcomes. FUNDING: Google.


Assuntos
Aprendizado Profundo , Retinopatia Diabética/diagnóstico , Idoso , Área Sob a Curva , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fotografação , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Medição de Risco/métodos
7.
IEEE Trans Pattern Anal Mach Intell ; 33(8): 1619-32, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21173445

RESUMO

In this paper, we address the problem of tracking an object in a video given its location in the first frame and no other information. Recently, a class of tracking techniques called "tracking by detection" has been shown to give promising results at real-time speeds. These methods train a discriminative classifier in an online manner to separate the object from the background. This classifier bootstraps itself by using the current tracker state to extract positive and negative examples from the current frame. Slight inaccuracies in the tracker can therefore lead to incorrectly labeled training examples, which degrade the classifier and can cause drift. In this paper, we show that using Multiple Instance Learning (MIL) instead of traditional supervised learning avoids these problems and can therefore lead to a more robust tracker with fewer parameter tweaks. We propose a novel online MIL algorithm for object tracking that achieves superior results with real-time performance. We present thorough experimental results (both qualitative and quantitative) on a number of challenging video clips.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...